{"id":9504,"date":"2025-03-13T09:48:09","date_gmt":"2025-03-13T08:48:09","guid":{"rendered":"https:\/\/cws.cz\/products-field\/covers\/"},"modified":"2025-04-17T21:01:37","modified_gmt":"2025-04-17T19:01:37","slug":"covers","status":"publish","type":"products-field","link":"https:\/\/cws.cz\/en\/products-field\/covers\/","title":{"rendered":"Covers"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">Frames<\/h2>\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p>The solid frames for <strong>ZEKAN<\/strong> covers have been oversized so that they can be used together with the covers even in the most demanding conditions. The frames are simply joined with a&nbsp;proven 8-point fastener system and the option of fixing with a&nbsp;construction bonding agent to ensure the joint is permanent. The frame design allows for customised cover assemblies starting with the smallest 335 x 600 clearance solution, with no upper limit, only depending on the specification of the installation.  <\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"866\" height=\"613\" src=\"https:\/\/cws.cz\/wp-content\/uploads\/2024\/05\/Ram-ZEKAN.webp\" alt=\"\" class=\"wp-image-1733\" srcset=\"https:\/\/cws.cz\/wp-content\/uploads\/2024\/05\/Ram-ZEKAN.webp 866w, https:\/\/cws.cz\/wp-content\/uploads\/2024\/05\/Ram-ZEKAN-300x212.webp 300w, https:\/\/cws.cz\/wp-content\/uploads\/2024\/05\/Ram-ZEKAN-768x544.webp 768w\" sizes=\"auto, (max-width: 866px) 100vw, 866px\" \/><\/figure><\/div><\/div>\n<\/div>\n\n<h2 class=\"wp-block-heading\">Covers<\/h2>\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"592\" height=\"422\" src=\"https:\/\/cws.cz\/wp-content\/uploads\/2024\/05\/Poklop-ZEKAN-XL-1.webp\" alt=\"\" class=\"wp-image-1102\" srcset=\"https:\/\/cws.cz\/wp-content\/uploads\/2024\/05\/Poklop-ZEKAN-XL-1.webp 592w, https:\/\/cws.cz\/wp-content\/uploads\/2024\/05\/Poklop-ZEKAN-XL-1-300x214.webp 300w\" sizes=\"auto, (max-width: 592px) 100vw, 592px\" \/><\/figure><\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p>The material for the production of covers is self-extinguishing, dimensionally stable, has high surface hardness, is hygienic, thermally insulating and non-magnetic. The covers can also be machined with conventional metal tools. <\/p>\n\n\n\n<p>The cover locking is solved in the standard version by means of a&nbsp;screw with metric thread and threaded sleeve mounted in the manhole body. It is possible to select a&nbsp;version with a&nbsp;classic M10 hexagon head screw or <strong>SECURITY<\/strong> <strong>TORX<\/strong> screws. <\/p>\n<\/div>\n<\/div>\n\n<h2 class=\"wp-block-heading\">In-paved covers<\/h2>\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p>Cast iron covers in the basic load classes are also used when the requirements for the uniformity of the cover design when installed in interlocking concrete pavement are met.<\/p>\n\n\n\n<p>A higher version of the perimeter frame shall be used so that it is flush with the stainless steel trays, which can be paved with paving to 10 cm high. If lower paving is used, such paving shall be underlain by a&nbsp;layer of inert material to the required height. <\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"587\" height=\"425\" src=\"https:\/\/cws.cz\/wp-content\/uploads\/2024\/05\/Poklopy-pro-zadlazdeni.webp\" alt=\"\" class=\"wp-image-1105\" srcset=\"https:\/\/cws.cz\/wp-content\/uploads\/2024\/05\/Poklopy-pro-zadlazdeni.webp 587w, https:\/\/cws.cz\/wp-content\/uploads\/2024\/05\/Poklopy-pro-zadlazdeni-300x217.webp 300w\" sizes=\"auto, (max-width: 587px) 100vw, 587px\" \/><\/figure><\/div><\/div>\n<\/div>\n\n<h2 class=\"wp-block-heading\">ZEKAN cast iron cover load capacity<\/h2>\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"724\" src=\"https:\/\/cws.cz\/wp-content\/uploads\/2024\/05\/CWS_schema-mesta_300DPI-1024x724.webp\" alt=\"\" class=\"wp-image-1108\" srcset=\"https:\/\/cws.cz\/wp-content\/uploads\/2024\/05\/CWS_schema-mesta_300DPI-1024x724.webp 1024w, https:\/\/cws.cz\/wp-content\/uploads\/2024\/05\/CWS_schema-mesta_300DPI-300x212.webp 300w, https:\/\/cws.cz\/wp-content\/uploads\/2024\/05\/CWS_schema-mesta_300DPI-768x543.webp 768w, https:\/\/cws.cz\/wp-content\/uploads\/2024\/05\/CWS_schema-mesta_300DPI-1536x1086.webp 1536w, https:\/\/cws.cz\/wp-content\/uploads\/2024\/05\/CWS_schema-mesta_300DPI-2048x1448.webp 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure><\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p>The distribution of the load capacity of covers and related structures is governed by <strong>EN 124<\/strong>, which distinguishes 6 load classes, marked with the letters <strong>A<\/strong> to <strong>F<\/strong>. The <strong>ZEKAN<\/strong> cable manholes system allows the use of the 2 most common load classes <strong>B125<\/strong> (12.5 tonnes) and <strong>D400<\/strong> (40 tonnes). <\/p>\n\n\n\n<p>The suitability of the use of each type is described in the above mentioned standard. The choice of a&nbsp;given load class is to some extent the responsibility of the responsible designer, depending on the specific conditions of the cable manhole location. The following figure is for basic orientation only.  <\/p>\n<\/div>\n<\/div>\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h2 class=\"wp-block-heading\">Advantages of cast iron covers:<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>shape and dimensional variability<\/li>\n\n\n\n<li>product strength and rigidity<\/li>\n\n\n\n<li>self-extinguishing ability<\/li>\n\n\n\n<li>colour finish surface according to RAL scale<\/li>\n\n\n\n<li>choice of surface \u2013 imitation concrete, high gloss or matt component<\/li>\n\n\n\n<li>surface hardness<\/li>\n\n\n\n<li>hygienic safety<\/li>\n\n\n\n<li>thermal insulator<\/li>\n\n\n\n<li>non-magnetic<\/li>\n\n\n\n<li>chemically and mechanically resistant<\/li>\n\n\n\n<li>low maintenance costs<\/li>\n\n\n\n<li>weatherproof<\/li>\n<\/ul>\n<\/div>\n<\/div>\n","protected":false},"template":"","meta":{"_acf_changed":false},"class_list":["post-9504","products-field","type-products-field","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/cws.cz\/en\/wp-json\/wp\/v2\/products-field\/9504","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cws.cz\/en\/wp-json\/wp\/v2\/products-field"}],"about":[{"href":"https:\/\/cws.cz\/en\/wp-json\/wp\/v2\/types\/products-field"}],"wp:attachment":[{"href":"https:\/\/cws.cz\/en\/wp-json\/wp\/v2\/media?parent=9504"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}